SNMP

The option ”SNMP” allows users to setup SNMP on an eyeInspect server, or to disable a previously enabled SNMP service for environments where SNMP is used to monitor server health status.

When configuring SNMP, sdconfig will allow the following settings to be applied:

Setting Details
Protocol versions Enable legacy protocol versions v1 and v2c, or only use v3
The SNMP username  
The SNMP user password  
The SNMP Encryption key Required for v3 only
SNMP user privileges Read-only or read-write
SNMP configuration details Optionally set system location, description and contact
Custom snmpd.conf lines Optionally set configuration lines to add to the /etc/snmp/snmpd.conf file

After applying these settings, SNMP will be operational on the eyeInspect server, and SNMP queries can be sent to it. Ensure that the firewall allows SNMP communication on port 161 between the SNMP monitoring system and the eyeInspect server.

Examples of SNMP queries that may be applicable for eyeInspect health status monitoring are given in the below table:

Metric SNMP OID
1 minute Load UCD-SNMP-MIB::laLoad.1
5 minute Load UCD-SNMP-MIB::laLoad.2
15 minute Load UCD-SNMP-MIB::laLoad.3
Installed memory UCD-SNMP-MIB::memTotalReal.0
Available memory UCD-SNMP-MIB::memAvailReal.0
Disk partition size UCD-SNMP-MIB::dskTotal.1
Disk partition free UCD-SNMP-MIB::dskAvail.1
Interface<interface index>BYTES IN F-MIB::ifHCInOctets.<interface index>
Interface<interface index>BYTES OUT IF-MIB::ifHCOutOctets.<interface index>
Interface<interface index>PACKETS IN IF-MIB::ifHCInUcastPkts.<interface index>
Interface<interface index>PACKETS OUT IF-MIB::ifHCOutUcastPkts.<interface index>
Interface MTU<interface index> IF-MIB::ifMtu.<interface index>
Interface MAC address<interface index> IF-MIB::ifPhysAddress.<interface index>
Interface promiscuous mode<interface index> IF-MIB::ifPromiscuousMode.<interface index>
Interface dropped packets<interface index> IF-MIB::ifInDiscards.<interface index>

For details on how to retrieve this information from an external SNMP monitoring system, please refer to the documentation provided by the monitoring system provider.